Show simple item record

dc.contributor.authorBerná Serna, JD
dc.contributor.authorMartínez, F.
dc.contributor.authorReus, M.
dc.contributor.authorAlonso, José
dc.contributor.authorDoménech, G.
dc.contributor.authorCampos, D.
dc.date.accessioned2025-01-31T14:31:59Z
dc.date.available2025-01-31T14:31:59Z
dc.date.issued2007
dc.identifier.citationBerná-Serna JD, Martínez F, Reus M, Alonso J, Doménech G, Campos M. Evaluation of the triangular fibrocartilage in cadaveric wrists by means of arthrography, magnetic resonance (MR) imaging, and MR arthrography. Acta Radiol. 2007 Feb;48(1):96-103. doi: 10.1080/02841850601045112es
dc.identifier.issn0284-1851
dc.identifier.issn1600-0455
dc.identifier.urihttp://hdl.handle.net/10952/9075
dc.description.abstractPurpose: To evaluate the diagnostic accuracy of arthrography, magnetic resonance (MR) imaging, and MR arthrography in the detection and localization of defects of the triangular fibrocartilage (TFC) in cadaveric wrists, using arthroscopy as a reference standard. Material and methods: Twenty-four specimen wrists were evaluated. The different imaging modalities were blinded to reviewers and were interpreted independently. A classification of TFC defects was used for the evaluation of images in the different imaging modalities, thus permitting a more uniform correlation. Two cases were excluded from the MR imaging study because of poor image quality. Contingency tables with the chi-square test and Fisher's exact test were used for statistical analysis. Results: Defects of the TFC were identified in 17 of the 24 specimen wrists by means of arthroscopy, and 16 defects were observed when arthrography was carried out. With MR imaging 14 defects of the TFC were detected in the 22 specimen wrists evaluated, and with MR arthrography 16 defects were observed. Most defects were central or combined (two or more defects). In comparison to arthroscopy, the accepted diagnostic gold standard, the following results were found for arthrography in the detection of TFC defects: sensitivity 95%, specificity 100%, and accuracy 95% (P<0.0005); for MR imaging: sensitivity 86%, specificity 85%, and accuracy 70% (P<0.002); and for MR arthrography: sensitivity 100%, specificity 85%, and accuracy 95% (P<0.0005). Conclusion: The results of the study seem to indicate that both arthrography and MR arthrography have high accuracy, and either would be useful for evaluation of the TFC. The combined approach using both techniques would have a very high accuracy equivalent to that resulting from arthroscopy.es
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEvaluation of the triangular fibrocartilage in cadaveric wrists by means of arthrography, magnetic resonance (MR) imaging, and MR arthrographyes
dc.typejournal articlees
dc.rights.accessRightsopen accesses
dc.journal.titleActa Radiologicaes
dc.volume.number48es
dc.issue.number1es
dc.description.disciplineMedicinaes
dc.identifier.doi10.1080/02841850601045112es
dc.description.facultyMedicinaes


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional