Mostrar el registro sencillo del ítem

dc.contributor.authorSánchez Ayllón, Francisca
dc.contributor.authorSegura Alba, Óscar
dc.contributor.authordos Santos Becerril, Manacés
dc.contributor.authorRojo Rojo, Andrés
dc.contributor.authorMelendreras Ruiz, Rafael
dc.contributor.authorAlcázar Artero, Mireia
dc.contributor.authorPujalte Jesús, María José
dc.contributor.authorDíaz Agea, José Luis
dc.date.accessioned2025-07-28T08:07:25Z
dc.date.available2025-07-28T08:07:25Z
dc.date.issued2022-08-23
dc.identifier.citationSánchez-Ayllón, F., Segura-Alba, O., Dos Santos-Bezerril, M., Rojo-Rojo, A., Melendreras-Ruiz, R., Alcázar-Artero, M., José Pujalte-Jesús, M., & Luis Díaz-Agea, J. (2022). Safety assessment of low-flow oxygenation device: Quasi-experimental study. Clinical Nursing Research, 31(8), 1431-1437. https://doi.org/10.1177/10547738221112745es
dc.identifier.issn1054-7738
dc.identifier.urihttp://hdl.handle.net/10952/10046
dc.description.abstractThe objective of this study was to verify the feasibility of using an Oxygenation Device with Reservoir and Positive End-Expiratory Pressure (ODRPEEP; DORPEEP in Spanish) and to analyze its safety with respect to mask leaks and carbon dioxide retention measured upon expiration. A quasi-experimental pilot study was designed with eight volunteers in two experiments to determine the degree of leaks from the device, according to the observation of water vapor particle diffusion, on the one hand, and of thermal images on the other. The results from this study showed that the mask from the DORPEEP© device at is tightest fit provided an adequate seal, although not fully airtight. In the thermal images and in the experiment with water vapor in our study, dispersions were mainly observed in the lower area in individuals with a beard. The DORPEEP© device was shown to have only slight leaks.es
dc.language.isoenes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOxygenation devicees
dc.subjectPositive end-expiratory pressurees
dc.subjectMask leakses
dc.subjectFeasibilityes
dc.subjectSafetyes
dc.titleSafety Assessment of Low-Flow Oxygenation Device: Quasi-Experimental Studyes
dc.typejournal articlees
dc.rights.accessRightsopen accesses
dc.journal.titleClinical Nursing Reseaches
dc.volume.number31es
dc.issue.number8es
dc.description.disciplineEnfermeríaes
dc.identifier.doi10.1177/10547738221112745es
dc.description.facultyEscuela Politécnicaes


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional